Send Email
Send SMS
Search
Sunshine Instruments
Sunshine Instruments


Thickness Gauge

Prominent & Leading Wholesale Trader from Coimbatore, we offer coating thickness gauge and tube thickness caliper.

Coating Thickness Gauge

REQUEST CALLBACK

Coating Thickness Gauge
Approx. INR 1000 / Onwards
Get Best Quote

We are one of the suppliers of a premium range of Coating Thickness Gauge. These products are designed in compliance with the set industry standards using qualitative raw material. These products are manufactured using modern technologies and widely acclaimed by clients for its high efficiency, long lasting durability, and advanced usage.

 

Features:

 

  • Fine Accuracy

  • Made as per Customer Satisfaction

  • Light weight metal used

  • Very long service life

  • Handles large pressure and variable temperature


Specifications:
Can be used in accordance with:
ASTM D 1186-AASTM G 12
ASTM B 499ASTM A 153
BS 5411-11BS 3900-C5-64b
DIN 50981ISO 2178
ISO 2808-6AbSSPC-PA2
Other Details:
Accuracy±5% of the reading or ±2.5pm/0.1 mils(whichever is the greater)
Minimum Substrate Thickness0.4 mm(16mils)
Minimum Area of Measurement30 mm(1.18°) Diameter
Minimum Diameter for Measurement on Bar Material20 mm(0.8”)
Edge EffectsMust be at least 6mm(0.24”) from edge
Instruments Dimensions200x60x30 mm(7.8x2.4x1.2”)
Certification AvailableCertificate of Conformance and Calibration Certificate
Yes! I am Interested

Coating Thickness Gauge

REQUEST CALLBACK

Coating Thickness Gauge
Approx. INR 1499 / Onwards
Get Best Quote

Statistics:

(Number of readings, average, Std, deviation, max, & min.) are updated with every reading and displayed simultaneously. It helps to decided how many readings are to be taken. Continue taking readings till you start getting reasonably consistent statistics.

  • Third party Test Report  to international standards.
  • Interchangeable probe sleeve tip(A) having 3 for flat & Spherical surface.
  • Interchangeable probe sleeve tip(B) having V block for cylindrical surfaces.
  • Auto-Off. If instrument remains unused for 2 minutes. It  switched off automatically. It saves battery.
  • Last calibration retained and Auto-retrieved.
  • Manipulation of readings not possible.
  • Models M have Hard-chrome Plated Probe tips and Models C have Probe tips of wear Resistant Material.
  • Spring loaded probe sleeve with tip ensures probe is held perpendicular.
  • A beep sound is heard when reading is obtained.
  • Low battery Indication-Display shows BAT continuously.

Features:

  • Models M2$,M6$ & M12$ 
  • For Non-magnetic coatings on magnetic base. Ideal for Coating on MS.
  • Model C2$ & C4$ 
  • For Non-conductive coatings on conductive base For 
  • Anodizing and Coatings of Brass & Aluminium
  • Model(M&C)2$
  • Combined Model of M2$ & C2$


Specifications:

 

  • Test Base: To check satisfactory working
  • Maximum number of readings: 254
  • Working Temperature:0 to 50 degree C
  • Supply Dry Battery:9V(6t22)
  • Display Digit Height:5.6 mm
  • Instrument Size:127x83x41 mm
  • Probe wire Length: -1000 mm
  • Socket for AC Adaptor
  • Wooden case

 



Yes! I am Interested

Tube Thickness Caliper

REQUEST CALLBACK

Tube Thickness Caliper
Approx. INR 1000 / Onwards
Get Best Quote

Features:

  • The main scale jaw is a round bar that facilitates measurements of tube wall thickness
  • With SPC data output

Technical Data:

  • Accuracy: Refer to the list of specifications.
  • Excluding quantizing error for digital models
  • Resolution*: 0.01 mm or .0005"/0.01 mm
  • Graduation**: 0.05 mm
  • Display*: LCD
  • Length standard*: ABSOLUTE electromagnetic induction
  • linear encoder
  • Max. response speed*: Unlimited
  • Battery*: SR44 (1 pc.), 938882
  • Battery life*: Approx. 3 years under normal use
  • Dust/Water protection level*: IP67
  • Digital models, Analog models

Function of Digital Model:

  • Origin-set, Zero-setting, Automatic power on/off, Data output, inch/mm conversion (inch/mm models)
  • Alarm: Low voltage, Counting value composition error

Optional Accessory for Digital Model:

  • 05CZA624: SPC cable with data switch (1 m)
  • 05CZA625: SPC cable with data switch (2 m)

 

Specifications:

 

Range Order No. Accuracy
0 - 150 mm 573-661 ±0.05 mm
0 - 150 mm 573-622* ±0.05 mm
Yes! I am Interested

View PDF

Coating Thickness Gauge

REQUEST CALLBACK

Coating Thickness Gauge
Approx. INR 1400 / Onwards
Get Best Quote

Coating Thickness Gauges are small in size, smart design, innovative and Hi-The Instruments

  • Suitable to Many Industries and Engineers for convenient to use and Operate, Designed to fit in either hand, light in weight, easy to carry. Although complex and advanced
  • Confirms to Standards of both ISO-2178 and ISO-2361 as well as DIN,ASTM &BS
  • Manual or Auto OFF Saves battery Life
  • Factory calibration, Calibration is easy  by zero & CAL buttons
  • Feather Touch Range Switches um/mil Selectable
  • Can perform two different Methods of Calculating coating Measurements by Utilizing the Characteristics of Both Eddy Current and Magnetic induction Both non-destructive and extremely accurate
  • With this Stale of the are Coating Thickness gauge, you can easily detect the thickness of nonmagnetic coating on a magnetic substrate(Ferrous) or Insulating Coating on a non-magnetic conductive substrate (non-Ferrous)
  • All the Coating Thickness Gauge are Compatible with P.C.interface RS 232C(Optional)

Specification:

Range 0-1250 um/0-50 mil (Selectable)
Resolution 0.1 um or 0.5 mil
Accuracy ±1-3% m or +/-2.5% um
Min Measuring Area 6 mm
Min.Sample Thickness 0.3 mm
Min.Radius of Curvature F:Convex 1.5 mm/Concave 25 mm N:Convex 3 mm Concave 50 mm
Power Source 4x1.5 V AAA(Um4) battery
Weight Main UNIT 85 grams(without Battery)
Standard Accessories “0” Calibration Base for F&;N, Calibration FOIL 4,
F&;N Probes for Mod:27FN
Packing Tough ABS Plastic Carrying Case
Optional RS 232C Software, Interface Cable
Yes! I am Interested

Coating Thickness Gauge

REQUEST CALLBACK

Coating Thickness Gauge
Approx. INR 1000 / Onwards
Get Best Quote

Product Description:

Can measure the thickness of non-magnetic coating layers of magnetic, such as:(aluminum, chrome, copper, enamel, rubber, plaint) on magnetic substrate(steel, iron, alloy and magnetic stainless steel), And can measure the thickness of non conductive coating layers covered on nonferrous substrate, such as:(ename1, rubber, paint, vanish, plastic anodic-oxide layer) covered Model: CM-8821, CM-882, CM-8823, CM-8825FN, CM-8825N, CM-8826FN, CM-8826F, CM-8826N, CM-829, CM-8829S

Features:

  • It meets the standard of ISO2178,DIN,ASTM AND BS.Suitable for the laboratory and for use in  field conditions.
  • The F probes measure the thickness of nonmagnetic materials(e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials(e.g. iron, nickel etc), often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminum tile, some alloy tile, paper etc.
  • Automatic substrate recognition
  • Manual or automatic shut down
  • Two measurement mode: Single and Continuous
  • wide measuring range and high resolution
  • Metric/imperial converse
  • Digital display gives exact reading with no guessing or errors
  • Can communicate with PC computer for statistic and printing by the optional cable and the software for RS232C interface
Yes! I am Interested

Coating Thickness Gauge

Coating Thickness Gauge
Approx. INR 1000 / Onwards
Yes! I am Interested



 
X


Call Us:  +91-8048602153
Sunshine Instruments
Devang Thakkar (CEO)
P.B. No. 3910, No. 83, Chinny's Chamber, Dr. Nanjappa Road Near Sony Erriscion Service Center,
Coimbatore - 641018, Tamil Nadu, India
Contact via E-mail
Contact via SMS



Home  |   Profile   |  Our Products  |  Site Map  |   Contact Us   |   Mobile Site

© Sunshine Instruments. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Sunshine Instruments