Our firm is among the leading reputed industry dealing in ION Specific Meter Hanna. Moreover, we offer the wide spectrum range of products such as ammonia Test Kit For Fresh Water, Hanna Free Chlorine Test Kit, Flouride HR-HI93739, Chemical Oxygen Analyzer, Hardness Meter, Oxygen ION Specific Meter. With the aid of complete endeavored professionals, we have developed innovative product range which manufactured with the best base materials. Furthermore, the rendered product line is obtainable at client friendly rates.
Range | LR 0 to 250 ppm MR 200 to 500 ppm HR 400 to 750 ppm |
Resolution | 1 ppm from 0 to 10 ppm 5 ppm from 100 to 750 ppm |
Accuracy | LR ±5 ppm or ±4% or reading, whichever is greater MR ±7 ppm or ±3% of reading, whichever is greater HR ±10 ppm or ±2% of reading, whichever is greater |
Typical EMC Deviation | ±5 ppm |
Light Source | Light Emitting Diode @ 470 nm |
Method | Adaptation for the EPA recommended method 130.1. The reaction between calcium, magnesium and the reagents causes a red-violet tint in the sample |
Light Detector | Silicon photo cell |
Environment | 0 to 50°C (32 to 122°F) max 95% RH non-condensing |
Battery Type/ Life | 1 x 9 volt/40 hours |
Auto-Shut off | After 10' of non-use |
Dimensions | 180 x 83 x 46 mm (7.1 x 3.3 x 1.8”) |
Weight | 290 g (10 oz.) |
Additional Information:
We are a prominent industry in catering the meets and demands of our clients of our best-in-class Hanna Free Chlorine Test Kit. The resources and the raw materials are attained from renowned vendors to ensure the best for our clients. Furthermore,the finest chemicals, leads to perfect Accuracy and best operation .These products which we supply come with a fine-finish,and the product are widely appreciated for its durability and accuracy.
Features:
Perfectly accurate
Fine-finish
Long lasting
High durability
Additional Information:
Additional Information:
Temperature of Reaction | 105°C or 105°C(22°F or 320°F) |
Temperature Stability | ±0.5°C |
Temperature Range | -10°C to 160°C |
Capacity | 25 vials (dia 16x100 mm), 1 for a Stainless steel reference thermometer |
Accuracy | ±2°C (@ 25°C/77°F) |
Additional Information:
Temperature of Reaction | 105°C or 105°C(22°F or 320°F) |
Temperature Stability | ±0.5°C |
Temperature Range | -10°C to 160°C |
Capacity | 25 vials (dia 16x100 mm), 1 for a Stainless steel reference thermometer |
Accuracy | ±2°C (@ 25°C/77°F) |
Additional Information:
Method | Titration |
Range | 0-30 gpg |
Smallest Increment | 1 gpg |
Chemical Method | EDTA |
Number of Tests | 100 |
Weight | 457 g |
Additional Information:
Additional Information: